Sign In
 
Search
Print Get Connected  
Automatic Operator Sensors & Accessories
WP_6238_590x332
OverviewSensors & AccessoriesAccessoriesDownloads

Select Sweets ProductTAG to Annotate Content

The sensors and accessories are to be used only with LCN automatic operators. When using sensors supplied by others, consult the factory. The desired function, traffic patterns and physical design of the opening will determine the type of sensors used.
Door Mount Safety Sensor, 8310-804-1
Contains one active sensor module to detect obstruction(s) on leading edge of door.
 
Door Mount Safety Sensor, 8310-804-2
Contains two active sensor modules to detect obstruction(s) on full face of door.
 
Header Mount Activation Sensor, 8310-854
Header Mount Activation Sensor, 'K' Band Technology Used to detect objects either approaching or moving away from sensor. Uses standard 'one way' detection but additional detection can be programmed. Optional 8310-859 Handheld Remote Control can be used to program 8310-854 sensor from a distance.
 
Header Mount Safety Sensor, 8310-877
Header Mount Safety Sensor, 'Diffused Infrared' Technology. Used to detect obstructions during door open and door closed position. Nine selectable patterns. Optional 8310-859 Handheld Remote Control can be used to program 8310-877 sensor from a distance. Includes 8310-846 Harness.
 
Header Mount Safety Sensor Spacer, 8310-877S
Required when 8310-804-1 or 8310-804-2 Door Mount Safety Sensors are used w/ 8310-877 Header Mount Safety Sensor.
 
Remote Control, Handheld, 8310-859
Used to program 8310-877 Header Mount Safety Sensor or 8310-854 Header Mount Motion Sensor.
 
Harness Header Mount, 8310-846
Used w/ 8310-877 Header Mount Safety Sensor.
 
Harness Door Mount, 8310-847
Used w/ 8310-804-1 or 8310-804-2 Door Mount Safety Sensor.
 
Safety Sensor Package, 8310-3880
Activation/Safety Sensor Package, High Energy, Single Door Includes 8310-854 (2) Header Mount Activation Sensor, 8310-877 Header Mount Safety Sensor, 8310-812 Safety Beam Set. Requires LCN Safety/Guide Rails. Used w/ Astro Swing High Energy Operators
 
Safety Sensor Package, 8310-3881L
Activation/Safety Sensor Package, Single Door Includes 8310-854 (2) Header Mount Activation Sensor, 8310-877 Header Mount Safety Sensor, 8310-877S Header Mount Spacer, 8310-804-2 Door Mount Safety Sensor (approach side), 8310-847 Harness
 
Safety Sensor Package, 8310-3881
Activation/Safety Sensor Package, Single Door Includes 8310-854 (2) Header Mount Activation Sensor, 8310-877 Header Mount Safety Sensor, 8310-877S Header Mount Spacer, 8310-847 Harness, 8310-804-2 (2) Door Mount Safety Sensor (approach/safety side)
 
Safety Sensor Package, 8310-3883
Activation/Safety Sensor Package, Low Energy Convenience, Single Door, Includes 8310-804-1 Door Mount Safety Sensor (approach side), 8310-805C Door Position Switch (Concealed), 8310-845 Programmable Relay Module
 
Safety Sensor Package, 8310-3882L
Activation/Safety Sensor Package, Double Door Includes 8310-854 (2) Header Mount Activation Sensor, 8310-877 Header Mount Safety Sensor, 8310-877S Header Mount Spacer, 8310-847 (2) Harness, 8310-804-2 (2) Door Mount Safety Sensor (approach side).
 
Safety Sensor Package, 8310-3882
Activation/Safety Sensor Package, Double Door Includes 8310-854 (2) Header Mount Sensor, 8310-877 Header Mount Sensor, 8310-877S Header Mount Spacer, 8310-847 (2) Harness, 8310-804-2 (4) Door Mount Safety Sensor (approach/safety side).
 
Safety Sensor Package, 8310-3891
Activation/Safety Sensor Package, Health Care I, Simultaneous Pair, Includes 8310-877 Header Mount Sensor, 8310-877S Header Mount Spacer, 8310-804-2 (4) Door Mount Sensor (approach/safety side), 8310-847 (2) Harness.
 
Safety Sensor Package, 8310-3892
Activation/Safety Sensor Package, Health Care II, Independent Pair, Includes 8310-877 (2) Header Mount Sensor, 8310-877S (2) Header Mount Spacer, 8310-804-2 (4) Door Mount Sensor (approach/safety side), 8310-847 (2) Harness
Switch, Door Position, Surface Mount, 8310-805
Used when 8310-804-1 or 8310-804-2 Door Mounted Safety Sensor is installed in conjunction w/ either a electrohydraulic or pneumatic Automatic Operator. Disables approach side sensor when door is closed.
 
Switch, Door Position, Concealed, 8310-805C
Used when 8310-804-1 or 8310-804-2 DoorMounted Safety Sensor is installed in conjunction w/ either a electrohydraulic or pneumatic Automatic Operator. Disables approach side sensor when door is closed.
 
Transformer, 24V, Hardwired, 8310-824
Optional accessory - Used to remotely power any 24v sensor/receiver
 
Transformer, 24V, Plug In, 8310-824P
Optional accessory - Used to remotely power any 24v sensor/receiver
 
Bracket, Drop Ceiling, 8310-854ECA
Optional bracket used w/ 8310-854 Header Mount Activation Sensor
 
Cover, Protective, 8310-854ERA
Optional cover used w/ 8310-854 HeaderMount Activation Sensor
 
Wireless Conversion Kit, Jambmount, 3V, 8310-3803
Converts standard jamb actuator to wireless version Requires 8310-819S or 8310-819F Jamb Box - Includes 8310-865 Receiver, 8310-844J (2) Jamb Mounted Transmitter
 
Wireless Conversion Kit,Wallmount, 9V, 8310-3809
Converts standard wall mount actuator to wireless version Requires Surface or Flush Box &Weather Ring - Includes 8310-865 Receiver, 8310-844 (2)WallMount Transmitter
 
Safety Module & Kit, 8310-3889
Used w/ 7901, 7902, 7981, 7982 Control Boxes Includes 8310-3888 Safety Module Harness. Required when 8310-877 HeaderMount Safety Sensor is used w/ Pneumatic Automatic Operators (2610, 4810, 4820 or 4840 Series)
 
Harness, Safety Module, Service Part, 8310-3888
Safety Module Harness for pneumatic control box.
 
Transmitter, Wireless, 8310-861
1 Channel, Handheld, 9v. Requires 8310-865 Receiver
 
Transmitter, Wireless, 8310-862
2 Channel, Handheld, 9v. Requires 8310-865 Receiver
 
Transmitter, Wireless, 8310-863
3 Channel, Handheld, 9v. Requires 8310-865 Receiver
 
Transmitter, Wireless, 8310-864
4 Channel, Handheld, 9v. Requires 8310-865 Receiver
 
Bollard Post, 8310-866
A powder coated steel, 42" x 4" x 6" Bollard Post, Mounting Base, Actuator Cut-Out Requires 8310-3853WB Bollard Actuator or 8310-3853TWB Bollard Actuator. Accepts any 4 3/4” square actuators. Includes 8310-866CAP.
 
Bollard Post, 8310-866CAP
Plastic Cap, Protective Cover, Service Part for 8310-866 Bollard Post
 
Switch, Key, 8310-806K
Type, 3 Position (On/Off/Hold-Open) Optional switch used w/ Senior Swing, Middle Swing, Astro Swing, Benchmark, or 4630/4640 Operators with (CS) option
 
Switch, Rocker, 8310-806R
Type, 3 Position (On/Off/Hold-Open) Optional switch w/ Senior Swing, Middle Swing, Astro Swing or Benchmark Operators.
 
Line Filter, 8310-807
AC, 120v, Optional filter used w/ Senior, Middle, Astro Swing Operators to reduce 'line noise'
 
Switch Adapter Harness, 8310-808
Used w/ 8310-806K or 8310-806R on Senior Swing, Middle Swing and Astro Swing Operators manufactured prior to 9/06
 
Programmable Relaymodule, 8310-845
Used to coordinate electric locking device release for Senior Swing, Middle Swing or Astro Swing Operators manufactured prior to 9/06. Also, is a component to the 8310-8337 Low Energy Convenience Package.