MA-Series Locks
WP_5815_590x332
OverviewStylesDownloadsCylinders/Key SystemsOptions/Accessories

Select Sweets ProductTAG to Annotate Content

The Falcon MA Series lock delivers high performance at an affordable cost in your office, hospital, education or other commercial projects. One of Falcon’s toughest, most dependable locks, the MA Series provides security and is built to stand up to constant use without fail. The MA Series also makes retrofit easy with an interchangeable core that can be removed for quick, easy re-keying and is compatible with SFIC products from other manufacturers. And they’re backed by one of the best names in the business.

Features and Benefits
• Provide mortise locksets that comply with ANSI A156.13, Series 1000, Operational Grade 1 and Security Grade 1 with all standard trims and conventional mortise cylinders.
• Locksets comply with UL10B - neutral pressure and UL10C/UBC 7-2 – positive pressure testing requirements. All locks shall be UL listed for 3 hour fire door.
• Lock case is non-handed, reversible without opening the lock case and manufactured of zinc dichromate plated steel. Lock case is interchangeable for knob or lever applications without modifying the chassis, and is constructed with a screw configuration that limits access to operating parts.
• Latchbolts are 2-piece anti-friction type manufactured from stainless steel, with a standard 2¾” backset, a full ¾” throw and are field reversible. Deadbolts have 1” throw and are constructed of stainless steel, incorporating two 3/16” diameter security roller pins.
• All trim are cast, forged, or wrought and through-bolted with thread patch coated screws. Lever trim has individual heavy duty springs for lever return, and independent rotation in both directions. Return to door style levers meet the ½” California State Fire Marshall requirement.
• Spindles are independent, designed to ‘break-away’ at a maximum of 480 in./lbs. to prevent damage to the lock chassis.
• Non-handed curved lip strikes are standard.
• Cylinders secured by a dual retainer.
• Acceptable manufacturer: FALCON Lock
Specifications
Door thickness:
Standard accommodates thickness of 1-3/8” to 2-1/2”.
Backset: 2-3/4” only.
Case: Cold formed steel, zinc dichromate plated, .090” thick. Optional lead wrapping available.
Hubs: Hardened steel.
Handing: Right hand is standard; left hand optional. Reversible in the field.
Cylinders: Solid brass cylinder and plug. 5, 6 or 7-pin are available on standard cylinders. 6 or 7-pin are available on interchangeable core cylinder. Furnished with two nickel silver keys standard
Keyways: “G” keyway standard on standard cylinder. “A” keyway standard on I/C cylinder. See price book for optional keyways
Bind Resistant Trim: Heavy-duty through-bolted inserts clamp the trim on the door assuring proper alignment. Provided with 8-32 screws for strength and thread sealant to prevent loosening.
Latch Bolt: Two-piece stainless steel, mechanical anti-friction bolt. 3/4” projection.
Dead Bolt: 1” throw, stainless steel with two 13/16” diameter hardened steel, free-turning, saw-resistant roller.
Faceplates: (Armored Front) 1-1/4” x 8” brass or stainless steel adjustable for door bevel. Reinforced by heavy gauge steel with stabilizing ribs.
Strike: Brass or stainless steel. Meets ANSI AII5.1 for frame preparation. Strike is non-handed.
Electrified Functions: Available in 12 or 24 VDC.
ANSI/BHMA: Meets ANSI/BHMA 156.13, Series 1000.
UL: 3 hour A label.
Levers/Knob and Trims
Falcon MA Series is available in several design combinations: “G” Gala rose or “N” Napa escutcheon with “H” Hana knob designation or four levers “A” Avalon, “D” Dane, “Q” Quantum and “S” Sutro. When specifying, combine knob or lever style with rose or escutcheon style - for example, AN = Avalon (A) Lever with Napa (N) escutcheon.
 
Number
A-Width
B-Projection
AG
4 1/2"
2 7/8"
DG
4 1/2"
2 1/2"
QG
4 3/4"
3"
SG
4 7/8"
3"
 
Number
A-Width
B-Projection
AN
4 1/2"
2 7/8"
DN
4 1/2"
2 1/2"
QN
4 3/4"
3"
SN
4 7/8"
3"
 
Lever Trim
Cast or forged levers (Avalon, Dane and Quantum) and wrought brass or stainless levers (Sutro), wrought rose and forged or wrought escutcheons are standard.
 
Knob Trim
Wrought knobs, wrought roses and forged or wrought escutcheons are standard.
 
Finishes
Falcon offers several finish choices to compliment the design elements of most any project. Falcon applies the best available protective plating or coating to the surface of our products to minimize the exposure to weather, pollution, perspiration, extremes of climate, frequency of us and other factors. Please consult with us if your building is subjected to chemical or corrosive conditions, as some finishes would not be recommended for these areas. Falcon recommends chrome plated or stainless steel finishes for high corrosive environments.
 
Trim Finishes Chart
Description
ANSI No.
Available on
Bright Brass
605
All Trim
Satin Brass
606
All Trim
Satin Bronze Oil Rubbed
613
All Trim
Bright Chrome
625
All Trim
Satin Chrome
626
All Trim
Satin Stainless Steel
630
All Trim
 

Catalog Number
ANSI
Function
Description
MA101
F 01
Passage or Closet Latch
Latch bolt operated by knob/lever from either side at all times.
MA161
F 31
Exit or Connecting Lock
Latch bolt operated by knob/lever from inside. No trim outside. Auxiliary dead latch.
MA301
F 02
Privacy, Bedroom/Bath
Latch bolt operated by knob/lever from either side. Dead bolt operated by turn from inside and by emergency release from outside.
MA311
F 19
Privacy, Bedroom/Bath
Latch bolt operated by knob/lever from either side. Dead bolt operated by turn from inside and emergency release from outside. Operating inside knob/lever retracts both bolts.
MA321
F 22
Privacy, Bedroom/Bath
Latch bolt operated by knob/lever from either side except when outside knob/lever is locked by inside turn. Operating inside knob/ lever, closing door or operating outside emergency release unlocks outside knob/lever.
MA371
F 14
Store Door Lock
Latch bolt operated by knob/lever from either side. Dead bolt operated by key from either side.
MA381
F 09
Apartment, Exit
Latch bolt operated by knob/lever from either side, except when outside knob/lever is locked by key from inside. When outside knob/ lever is locked, latch bolt is retracted by key from outside or by operating inside lever. Auxiliary dead latch.
MA411
F 30
Asylum or Institutional Lock
Latch bolt operated by key from either side. Both knobs/levers always inoperative. Auxiliary dead latch.
MA431
F 34
Classroom Security with Deadbolt
Latch bolt operated by knob/lever from either side except when outside knob/lever is locked from inside or outside by key. Dead bolt retracted by key from inside or outside. Operating inside knob/lever retracts both bolts and unlocks outside. Latch bolt dead locked when dead bolt is thrown.
MA441
F 32
Classroom Security Lock
Latch bolt operated by knob/lever from either side except when outside knob/lever is locked from inside or outside by key. When outside knob/ lever is locked, latch bolt is retracted by key from inside or outside or by operating inside knob/lever. Auxiliary dead latch.
MA451
F 15
Hotel Guest Lock
Latch bolt operated by key from outside or by operating inside knob/lever. Outside knob/lever is always inoperative. Dead bolt projected by turn from inside and all keys except emergency key are shut out. Operating inside knob/lever retracts both bolts. Auxiliary dead latch.
MA521
F 04
Entry/Office Lock
Latch bolt operated by knob/lever from either side except when outside knob/lever is made inoperative by buttons in face. When outside knob/lever is locked, latch bolt is retracted by key from outside or by operating inside knob/lever. Auxiliary dead latch. Outside knob/lever is unlocked by button on face.
MA531
F 12
F 20
Apartment Corridor Door Lock
Latch bolt operated by knob/lever from either side, except when outside knob/lever is made inoperative by buttons in face. Dead bolt operated by key outside or turn inside. Key outside operates both bolts. Operating inside knob/lever retracts both bolts and outside remains locked. Latch bolt is deadlocked when outside knob/lever is made inoperative or when the dead bolt is projected. When dead bolt is retracted, knob/lever is unlocked by buttons in face.
MA541
F21
Room Door Lock
Latch bolt operated by knob/lever from either side. Dead bolt operated by key from outside or turn from inside.
MA551
F06
Holdback Lock
Latch bolt operated by lever from either side except when outside lever is locked from outside by key. Latch bolt can be locked in a retracted position by key. When outside lever is locked, latch bolt is retracted by key from outside or by operating inside lever unless latch bolt has been locked in a retracted position. Auxiliary dead latch. Note: Chassis is handed. To activate the Holdback Function – from the unlocked position rotate the outside lever/knob to retract the latchbolt. Rotate key 360 degrees. Release lever/knob. To release Holdback Function, rotate key 360 degrees clockwise.
MA561
F05
Classroom Lock
Latch bolt operated by knob/lever from either side except when outside knob/lever is locked from outside by key. When outside knob/lever is locked, latch bolt is retracted by key from outside, or by operating inside knob/lever. Auxiliary dead latch deadlocks latchbolt when door is closed. Inside knob/lever always free for immediate exit.
MA571
F13
Dormitory or Exit Lock
Latch bolt operated by knob/lever from either side. Dead bolt projected by key from outside and turn from inside. Operating inside knob/lever retracts both bolts and unlocks outside.
MA581
F07
Storeroom Lock
Latch bolt operated by key from outside or by operating inside knob/lever. Outside knob/lever is always inoperative. Auxiliary dead latch.
MA621
F 08
F 10
Front Door/Apartment Corridor
Latch bolt is operated by knob/lever from either side, except when outside knob/lever is made inoperative by buttons in face. Dead bolt is operated by turn inside. Key outside operates both bolts. Outside knob/ lever is unlocked by button on face.
MA641
NA
Dormitory Lock
Latch bolt by knob/lever inside and key outside. Inside knob/lever free. Outside knob/lever rigid. Deadbolt by key outside or T-turn inside. Rotating inside knob/lever retracts both bolts. Deadlocking latch.
MA851
NA
Storeroom Fail Safe
(EL-12 & 24 VDC)
Latch bolt operated by knob/lever from either side except when outer knob/lever is electrically locked. When outer knob/lever is locked, latch bolt retracted by key in cylinder outside. Deadlocking latch.
MA881
NA
Storeroom Fail Secure
(EU - 12 & 24 VDC)
Latch bolt operated by knob/lever from inside except when outer knob/ lever is electrically unlocked, then latch bolt from either side. When locked, key in cylinder outside retracts latch bolt. Deadlocking latch.
MA911
F29
Classroom Dead Lock
Key from outside operates dead bolt. Turn from inside retracts but does not project dead bolt.
MA921
F18
Dead Lock
Dead bolt operated by key from outside only.
MA931
F16
Dead Lock
Dead bolt operated by key from either side.
MA941
F17
Dead Lock
Dead bolt operated by key from outside and by turn from inside.
MA12
NA
Single Dummy
Single Dummy Trim
MA18
NA
Double Dummy
Double Dummy Trim

 
MA Series Conversion Chart
MA Series Grade 1 Mortise Locks
 
ANSI No./Grade
Function
Falcon
Arrow
Best
Cal-Royal
Corbin/Russwin
Dorma
Marks
Sargent
Yale
F 01
MA101
Passage or Closet Latch
A-B01
45N
M8010
ML2010
9010
5-55N
8215
8801
F 02
MA301
Privacy, Bedroom/Bath
-
45LB
M8040
ML2020
-
5-55L
8268
-
F 04
MA521
Entry Lock
A-B22
45A
M8050
ML2051
9050
5-55E
8205
8807
F 05
MA561
Classroom Lock
A-B17
35R
M8070
ML2055
9070
5-55J
8237
8808
F 06
MA551
Holdback Lock
-
45RHB
-
ML2056
9076
5-55JM/JR
8289
8824
F 07
MA581
Storeroom/Closet Lock
A-B12
45ED
M8080
ML2057
9080
5-55EW
8204
8805
F 08/F 10
MA621
Front Door/Apartment Corridor
A-B21
45BA
-
ML2048
-
5-55A
8247
8747
F 09
MA381
Apartment, Exit
A-B32
45C
M8060
ML2042
9060
5-55G
8216
8817-2
F 12/F 20
MA531
Apartment Corridor Door Lock
A-B20
45AB
M8453
ML2067
9953
5-55FD
8243
8847
F 13
MA571
Dormitory or Exit Lock
A-B19
45FT
M8456
ML2065
9956
5-55FW
8225
8822
F 14
MA371
Store Door Lock
A-B31
45G
M8466
ML2022
9966
5-55C
8226
8860-2
F 15
MA451
Hotel Guest Lock
A-B15/16
45H/HJ
-
ML2029
9985
5-55H
8250
8820
F 16
MA931
Dead Lock
A-B42
45WD
-
ML2012
9962
5-55T
8222
8814-2
F 17
MA941
Dead Lock
A-B41
45AD
-
ML2013
9960
5-55P
8221
8815
F 18
MA921
Dead Lock
A-B40
45YD
-
ML2011
9961
5-55S
8220
8814
F 19
MA311
Privacy, Bedroom/Bath
A-B02
45L
M8040
ML2030
9940
5-55LF
8266
8802
F 21
MA541
Room Door Lock
A-B13
45B
M8473
ML2024
9973
5-55B
8224
8860
F 22
MA321
Privacy, Bedroom/Bath
A-B26
-
M8040
ML2060
9040
5-55LJ
8265
8862
F 29
MA911
Classroom Dead Lock
-
45RD
-
-
9963
5-55SC
8203
8813ST
F 30
MA411
Asylum or Institutional Lock
A-B33
45W
-
-
9082
5-55WW
8217
8830-2
F 31
MA161
Exit or Communicating Lock
-
45Y
-
-
9025
5-55EX
8213
8828
F 32
MA441
Intruder Latch Bolt Lock
A-B37
45INL
-
ML2052
9071
5-55GC
8238
8808-2
F 34
MA431
Intruder Dead Bolt Lock
-
-
-
-
9967
-
8240
8812-2
NA
MA12
Single Dummy
451DT
M8170
ML2050
-
-
8293
855/855FL
NA
MA18
Double Dummy
-
452DT
-
ML2070
-
-
8294
836B/838FL
NA
MA851
Storeroom - Fail Safe (EL - 12&24 VAC or VDC)
A-B17-177
45EWEL
-
ML20903
9080EL
5-55EL
8270
8880
NA
MA881
Storeroom - Fail Secure (EU - 12&24 VAC or VDC)
A-B17-178
45EWEU
-
ML20905
9080EU
5-55EU
8271
8881
NA
MA641
Dormitory Lock
-
45FD
-
-
-
-
-
-
 
 
Sliding Door Pulls Template
 
Installation Instructions
H Series
Installation Instructions -(Note: The file will be 11x17 if printed.) WD-0D002(045)
   
M Series
Installation Instructions - Lock with trim one side 030255-000-70
Installation Instructions - Dummy - Single & Double 030254-000-70
Installation Instructions - Locks with sectional & escutcheon trim 030216-000-70A
   
MA Series
Installation Instructions Q513-067
   
T Series
Installation Instructions 030794-000-70
   
X Series
Installation Instructions 002290-000-70
   
D Series
Installation Instructions - Cylinder Deadbolt Q513-062
Installation Instructions - Thumbturn Deadbolt Q513-080
Installation Instructions - Thumbturn Deadbolt-Single Side Q513-084
   
RU Series
Installation Instructions 031534-000-70
   
B Series
Installation Instructions 031728-000-70
   
W Series
Installation Instructions - Lever Q513-048-A
Installation Instructions - Knob Q513-050-A
Installation Instructions - Dummy Q513-052-A
   
Y Series
Installation Instructions Q513-036
Installation Instructions - Dummy Trim Q513-037

Templates

MA-Series
DESCRIPTION DOOR TYPE TEMPLATE
All Functions
Q005-083-Sectional  (All) FMA
Q005-084-Escutcheon  (All) FMA

M-Series - DISCONTINUED
DESCRIPTION DOOR TYPE TEMPLATE
Sectional (Rose) and Escutcheon (Napa) by Function
Lock Case Dimensions  (All) FM1
M101, M161  (Wood) FM100
M101, M161  (Metal) FM101
M301, M311, M321  (Wood) FM102
M301, M311, M321  (Metal) FM103
M371, M381, M411, M431, M441  (Wood) FM104
M371, M381, M411, M431, M441  (Metal) FM105
M451, M711  (Wood) FM106
M451, M711  (Metal) FM107
M521, M561, M581, M851, M881  (Wood) FM108
M521, M561, M581, M851, M881  (Metal) FM109
M531, M541, M571, M621, M641  (Wood) FM110
M531, M541, M571, M621, M641  (Metal) FM111
M941  (Wood) FM112
M941  (Metal) FM113
M921  (Wood) FM114
M921  (Metal) FM115
M911, M931  (Wood) FM116
M911, M931  (Metal) FM117
M12  (Wood) FM118
M12  (Metal) FM119
M18  (Wood) FM120
M18  (Metal) FM121
 
Information for all function
Lead Wrapping  (Wood)
Latchbolt, Auxiliary Deadlatch & Deadbolt Positions  (Metal)
Electrified Mortise Lock Wire Location  (Metal)

STRIKES
DESCRIPTION STANDARD SERIES OPTIONAL SERIES DOOR TYPE TEMPLATE
Q330-151, Q001-049 Full lip, Square Corner    B, H, T, W, X, Y  Wood Jamb FJ100
Q330-151, Q001-049 Full lip, Square Corner    B, H, T, W, X, Y  Metal Jamb FJ101
Q330-150, Q001-048 Full lip, Round Corner, 1/4" radius    B, H, T, W, X, Y  Wood Jamb FJ102
Q330-150, Q001-048 Full lip, Round Corner, 1/4" radius    B, H, T, W, X, Y  Metal Jamb FJ103
10-095, 005051 Full lip, Square corner, deadbolt    D100, D200  Wood Jamb FJ104
10-095, 005051 Full lip, Square corner, deadbolt    D100, D200  Metal Jamb FJ105
10-092, 005051-001, Full lip, Round corner, 1/4" radius, deadbolt    D100, D200, H  Wood Jamb FJ106
10-092, 005051-001, Full lip, Round corner, 1/4" radius, deadbolt    D100, D200, H  Metal Jamb FJ107
010018-001, 10-094, Square corner, deadbolt  D100, D200, H    Wood Jamb FJ108
010018-001, 10-094, Square corner, deadbolt  D100, D200, H    Metal Jamb FJ109
030020, ASA, deadbolt    D100, D200  Wood Jamb FJ110
030020, ASA, deadbolt    D100, D200  Metal Jamb FJ111
10-064, Drive-in thimble    D100, D200  Wood Jamb FJ112
005164, A21315/6/7, Q330-148, Square corner, ANSI & Mortise  B, M, RU, T, W, X  D100, D200, H, Y  Wood Jamb FJ113
005164, A21315/6/7, Q330-148, Square corner, ANSI & Mortise  B, M, RU, T, W, X  D100, D200, H, Y  Metal Jamb FJ114
031471/2/3, 03-471 3-1/4" Single door special    RU  Wood Jamb FJ115
031477 Special with stop    RU  Wood Jamb FJ116
031474 4-13/16" Single door special    RU  Wood Jamb FJ117
Q001-046, Q330-149, 5183/5/6/7/8/9, 5075 T-Strike  H, Y  B, T, X, W  Wood Jamb FJ118
Q001-046, Q330-149, 5183/5/6/7/8/9, 5075 T-Strike  H, Y  B, T, X, W  Metal Jamb FJ119
30290 4 Hole security    D100, D200  Wood Jamb FJ120
10-103, 1" Round Corner, 1/4" radius, no box, Deadbolt    D100, D200  Wood Jamb FJ121
10-104, 1-1/4" Round Corner, 1/4" radius, 4 holes, no box Deadbolt    D100, D200  Wood Jamb FJ122
10-108, Round Corner, 1/4" radius, no box, Deadbolt    D100, D200  Wood Jamb FJ123
31448, Pair of doors, 4 holes, no box    RU  Wood Jamb FJ124
31449, Pair of doors, 2 holes, no box    RU  Wood Jamb FJ125
5183/5/6/7/8/9 - 4, T-Strike, Round Corner, 9/16" radius    T, X  Wood Jamb FJ126
 
Miscellaneous (Sliding Door Pulls)
C979 Cabinet Lock      (Wood)
RU Series Installation Instructions       031534-000-70

Mortise Cylinders - Standard
Only the finest materials are used in the manufacture of our cylinders. Modern equipment and gauging ensure consistent, reliable production of our entire line of cylinders. We offer a full and complete line of spacer rings, cylinder guards and spring washers, as well as numerous cams to fulfill the requirements of most applications. Standard mortise cylinders are furnished as 5- or 6-pin as standard. 7-pin cylinders are available. All keyed cylinders are supplied with two nickel silver keys.
 
Standard Core MA Series Function/Cam Chart
Catalog Number
Outside Cam No.
Inside Cam No.
MA371
5622
5622
MA381
5620
MA411
5622
5622
MA431
5622
5622
MA441
5622
5622
MA451
5622
MA521
5622
MA531
5622
MA541
5622
MA551
5622
MA561
5622
MA571
5622
MA581
5622
MA621
5622
MA641
5622
MA851
5622
MA881
5622
MA911
5622
MA921
5622
MA931
5622
5622
MA941
5622
 
Cam Numbers
5622 = standard cam
5620 = F09 standard Inside
5621 = F09 standard Outside
 
Catalog Number
Standard Cylinders
Length
985
1 1/8"
987
1 3/8"
988
1 1/2"
990
1 3/4"
992
2"
 
Hotel/Motel Cylinders
250
1 1/8" RH
6-pin
251
1 1/4" RH
6-pin
252
1 3/8" LH
6-pin
253
1 3/8" LH
7-pin
 
Special hotel/motel cylinders, furnished with cam A09894-001-00.
Note: To order cylinder separately, order by listing catalog number for required length and cam number as indicated in chart above. Also, specify finish and number of pins.
EXAMPLE: 986 with A09897-000-00, 626, 6-pin
 
Mortise Cylinders — Interchangeable Cores
All Falcon MA Series keyed locks are available with mortise cylinders that will accept Falcon small format interchangeable cores (SFIC) as well as some other manufacturers’ SFIC. Interchangeable core cylinders are available in 6- or 7-pin configurations, for increased security by quick change of keying. Interchangeable core cylinders allow the capability of immediately changing the keying on any door without the necessity of disassembling the lock. The core is removed by use of a special “control” key. Rotating the key to the right and gently pulling will disengage the core from the housing. The replacement core is then inserted and the control key rotated to the left to “lock” the core in place and the control key is removed.
To order: Falcon mortise locks with interchangeable cores, add “G” 6- or 7-pin in detail area of order.
To order: Falcon mortise locks for interchangeable core, less core (SFIC), add “B” 6- or 7-pin in detail area of order.
 
Interchangeable Core MA Series Function/Cam Chart
Catalog Number
Outside Cam No.
Inside Cam No.
MA371
5622-IC
5622-IC
MA381
5621-IC
5620-IC
MA411
5622-IC
5622-IC
MA431
5622-IC
5622-IC
MA441
5622-IC
5622-IC
MA451
5622-IC
MA521
5622-IC
MA531
5622-IC
MA541
5622-IC
MA551
5622-IC
MA561
5622-IC
MA571
5622-IC
MA581
5622-IC
MA621
5622-IC
MA641
5622-IC
MA851
5622-IC
MA881
5622-IC
MA911
5622-IC
MA921
5622-IC
MA931
5622-IC
5622-IC
MA941
5622-IC
 
Cam Numbers
5622-IC = interchangeable cam
5620-IC = F09 Interchangeable Inside
5621-IC = F09 Interchangeable Outside
 
Catalog Number
Standard Cylinders
Length
C987
1 3/8"
C988
1 1/2"
C990
1 3/4"
C992
2"
 
Hotel/Motel Cylinders
C261
1 1/2" RH
C262
1 5/8" RH
C264
1 1/2" LH
C265
1 5/8" LH
 
Special hotel/motel cylinders, furnished with cam A09894-001-00.
Note: To order cylinder separately, order by listing catalog number for required length and cam number as indicated in chart above. Also, specify finish and number of pins.
EXAMPLE: 986 with A09897-000-00, 626, 6-pin
 
Cylinder Guards
Falcon offers two different types of cylinder guards in various thicknesses to work with sectional or escutcheon trim, different door ranges and various cylinder lengths. Our standard cylinder, 985, is 1-1/8” long. The factory will furnish the correct cam(s) and cylinder guard for the function and door thickness specified.
 
Escutcheon Trim Ring
Door Thickness
Function
985
1 1/8"
986
1 1/4"
(c)987
1 3/8"
(c)988
1 1/2"
1 1/2"
Single cylinder
-
A08790-000
A08790-001
A08790-002
1 1/2"
Double cylinder
A08790-000
-
-
-
1 3/4"
Single cylinder
-
-
A08790-000
A08790-001
1 3/4"
Double cylinder
-
A08790-000
A08790-001
A08790-002
2"
Single cylinder
-
-
A08790-000
A08790-001
2"
Double cylinder
-
-
A08790-000
A08790-001
2 1/4"
Single cylinder
-
-
-
A08790-000
2 1/4"
Double cylinder
-
-
-
-
2 1/2"
Single cylinder
-
-
-
-
2 1/2"
Double cylinder
-
-
-
-
 
Sectional Trim Ring
Door Thickness
Function
985
1 1/8"
986
1 1/4"
(c)987
1 3/8"
(c)988
1 1/2"
1 1/2"
Single cylinder
A08794-001
A08794-002
-
-
1 1/2"
Double cylinder
A08794-002
A08794-003
-
-
1 3/4"
Single cylinder
A08794-000
A08794-001
A08794-002
-
1 3/4"
Double cylinder
A08794-001
A08794-002
A08794-003
-
2"
Single cylinder
-
A08794-000
A08794-001
A08794-002
2"
Double cylinder
A08794-000
A08794-001
A08794-002
A08794-003
2 1/4"
Single cylinder
-
-
A08794-000
A08794-001
2 1/4"
Double cylinder
-
A08794-000
A08794-001
A08794-002
2 1/2"
Single cylinder
-
-
-
A08794-000
2 1/2"
Double cylinder
-
-
A08794-000
A08794-001
Specify part number and finish when ordering. (e.g. A08790-000-626)* Single cylinder functions.
 
Rim Cylinder Tailpieces
Dim. A
Dim. B
Part No.
3/32"
9/32"
A08790-000
7/32"
13/32"
A08790-001
11/32"
17/32"
A08790-002
15/32"
21/32"
A08790-003
43/64"
55/64"
A08790-004
Wave washer included. To order separately, specify 008789-001-60.
 
Dim. A
Dim. B
Part No.
3/32"
9/32"
A08794-000
7/32"
13/32"
A08794-001
11/32"
17/32"
A08794-002
15/32"
21/32"
A08794-003
Wave washer included. To order separately, specify 008789-001-60.
 
Dim. A
Dim. B
Part No.
1/8"
-
008876-000
3/16"
-
008876-005
1/4"
-
008876-001
3/8"
-
008876-002
1/2"
-
008876-003
5/8"
-
008876-004
 
Construction Keying
Falcon offers two different construction key systemsdepending on the size of and application within the project. Both systems permit the installation and use of regular door locks during construction, yet completely preserve the security of the keying system for the ultimate building owner. The Master, Grand Master and change keys are never with the locks during the construction phase of a building. Only the “construction” keys are sent to the job site. Where the job permits, we will utilize the “Lost Pin System” as our standard system for construction keying. Larger or more complicated jobs may require the use of our “Blockokey® System” for construction keying.

“Disposable Construction” Interchangeable Cores
This newly designed disposable construction core (1408) is an inexpensive alternative to interior keyed construction cores. This core should be used on interior door applications or where security on a site is not a concern. No keys need to be issued. The disposable core is inserted in the lever or knob and is operated by a thumb turn, which retracts the latch bolt. Please use either brass or permanent construction cores on exterior doors or secured areas.

Locks with ”Lost Pin System”
Our “lost” pin construction key system consists of one construction pin and a shallow hole in the side of the plug.

Construction Key—KB566
When the “construction” key is used, the construction pin is always in the cylinder plug, sitting on top of the bottom pin. consists of one construction pin and a shallow hole in the side of the plug.

Master Key—KB578
When the Master key is inserted, the construction pin is pushed up into the cylinder housing. As the Master key is rotated to the right, the construction pin will drop into the hole in the plug, thereby eliminating any future use of the construction key.

Locks with Blockokey® Cylinders
All lock cylinders on a specific project are operable by a special “project key.” Duplicates of this key may be assigned by the building contractor to workmen and subcontractors as required. No regular change keys or Master keys are needed on the job. This eliminates the possibility of subsequent exposure from lost or stolen keys.

How Locks with Blockokey® Cylinders are Used
Project Key—KB531
Lock cylinder is operated by the special ”project key.” The last two pins in the cylinder are held inoperative by the key block.

Removal Tool—KB536
The special ”project key” is canceled out by removal of the key block. A key block removal tool is furnished with the Master keys for the locks. Simply push the removal tool into the keyway, then withdraw it to remove the block. Thereafter, the ”project key” will no longer operate the lock cylinder.

Change or Master Key—KB578
Cylinder is now only operable by the regular change key or Master key.
Trim Options
 
Abrasive Coated Knobs and Levers
All knobs and levers are available with abrasive coating to identify entrances to hazardous areas to the handicapped.

Knurled Levers
Levers are available knurled to identify entrances to hazardous areas to the handicapped.

Lead Wrapping
MA Series locksets and latchsets are available with lead-wrapping for use on X-ray room doors (or similar situations).

Trim Packages
Both knob and lever trim packages are available to allow complete replacement of inner and outer trim on any lock function. Packages include inside and outside trim, spindle and mounting screws. Please see current price book for more details.

Strikes
Manufactured from heavy gauge brass or stainless steel. Meets ANSI Standard A115.1 for frame preparation. Strikes are available with various lip lengths.
 
Thumb Turn/Threaded Cylinders (Sold Separate)
Standard thumb turn threaded cylinders for dead bolt operation of MA Series locks may be used in lieu of surface mounted thumb turns. Furnished with A09894-1 cam. Available in length indicated and all MA Series finishes.